{"id":50,"date":"2016-09-12T18:26:12","date_gmt":"2016-09-12T15:26:12","guid":{"rendered":"http:\/\/langmuir.plasma.uaic.ro\/?page_id=36"},"modified":"2020-12-10T15:31:53","modified_gmt":"2020-12-10T13:31:53","slug":"l1-echipamente","status":"publish","type":"page","link":"https:\/\/cernesim.uaic.ro\/index.php\/language\/ro\/l1-ro\/l1\/l1-echipamente\/","title":{"rendered":"L1 &#8211; Echipamente"},"content":{"rendered":"<p><img loading=\"lazy\" class=\"size-medium wp-image-1146 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-300x172.png\" alt=\"\" width=\"300\" height=\"172\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-300x172.png 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-1024x587.png 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-768x440.png 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-1536x881.png 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1-624x358.png 624w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture1.png 1831w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Difractometru de raze X pentru monocristale cu surs\u0103 dual\u0103, SuperNova, Agilent Technologies, UK<\/strong><\/p>\n<p>Difractometrul este prev\u0103zut cu o surs\u0103 dual\u0103 (Nova\u2122 &#8211; Cu \u0219i Mova\u2122 &#8211; Mo), ideal\u0103 pentru analiza cristalelor care con\u021bin at\u00e2t atomi cu o densitate electronic\u0103 redus\u0103 c\u00e2t \u0219i atomi cu o densitate electronic\u0103 ridicat\u0103.<\/p>\n<p>Instrumentul are capacitatea de colectare a datelor, de rezolvare \u0219i rafinare a structurilor pentru diverse probe de natur\u0103 organic\u0103, anorganic\u0103, a compu\u0219ilor organo-metalici \u0219i a macromolecule cristaline utiliz\u00e2nd metode direct.<\/p>\n<p>Difractometrul este prev\u0103zut cu un goniometru cu 4 axe de rota\u021bie capabil s\u0103 asigure pozi\u021bionarea motorizat\u0103 precis\u0103 \u0219i reproductibil\u0103 a axelor Phi, Kappa, Omega, Theta, dar \u0219i a distan\u021bei prob\u0103-detector.<\/p>\n<p>Detectorul de tip CCD \u2013 EoS permite \u00eenregistrarea informa\u021bilor pentru un domeniul angular cuprins \u00eentre 0\u00b0 &#8211; 108\u00b0 (utiliz\u00e2nd microsursa Nova\u2122 &#8211; Cu), suficient pentru atingerea unei rezolu\u021bii \u00eenalte de 0.837 \u00c5, valoare minim\u0103 recomandat\u0103 de IUCr (International Union of Crystallography).<\/p>\n<p><img loading=\"lazy\" class=\"size-medium wp-image-1148 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture2-300x199.png\" alt=\"\" width=\"300\" height=\"199\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture2-300x199.png 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture2-768x510.png 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture2-624x414.png 624w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture2.png 942w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Spectrometru de Rezonan\u021b\u0103 Magnetic\u0103 Nuclear\u0103 (RMN), Ascend 500, Bruker, Germania<\/strong><\/p>\n<p>Spectrometrul RMN Bruker Ascend 500 MHz este creat \u00een jurul unui concept digital avansat care ofer\u0103 spectroscopie de mare vitez\u0103, flexibilitate \u0219i \u00eenregistrarea de spectre RMN cu acurate\u021be m\u0103rit\u0103, tehnica RMN \u00een pulsuri \u0219i folosirea transformatei Fourier amelioreaz\u0103 raportul semnal\/zgomot \u0219i reduce timpul de lucru.<\/p>\n<p>Spectrometrul RMN este prev\u0103zut cu magnet supraconductor ecranat activ cu un c\u00e2mp magnetic de 11,7 Tesla \u0219i cu deschidere interioar\u0103 de 54 mm. \u00cenregistrarea spectrelor se poate realiza cu diferite capuri de prob\u0103: BBO de 5 mm, pentru cinci nuclee <sup>1<\/sup>H\/<sup>13<\/sup>C\/<sup>15<\/sup>N\/<sup>19<\/sup>F\/<sup>31<\/sup>P cu detec\u021bie direct\u0103 \u0219i gradien\u021bi pe axa z; BBI de 5 mm, multinuclear cu detec\u021bie invers\u0103 pentru <sup>1<\/sup>H, <sup>13<\/sup>C \u0219i band\u0103 larg\u0103 de frecven\u021be, cu gradien\u021bi pe axa z; TXI de 1 mm cu detec\u021bie invers\u0103 (<sup>1<\/sup>H\/<sup>13<\/sup>C\/<sup>15<\/sup>N) cu z gradien\u021bi.Se pot efectua experimente la diferite temperaturi: pentru BBO \u0219i BBI domeniul -150 <sup>o<\/sup>C la +150 <sup>o<\/sup>C, iar pentru TXI domeniul -50 <sup>o<\/sup>C la +80 <sup>o<\/sup>C, cu limitarea domeniului de temperatura 0 <sup>o<\/sup>C la 80 <sup>o<\/sup>C \u00een sistemul de shimm.<\/p>\n<p>Experimente ce pot fi \u00eenregistrate \u00een siguran\u021b\u0103 pentru aparat \u0219i cu r\u0103spuns bun pentru o gam\u0103 larg\u0103 de compu\u0219i chimici solubiliza\u021bi \u00een solven\u021bi deutera\u021bi sunt <sup>1<\/sup>H-RMN, <sup>13<\/sup>C-RMN, DEPT 135 \u0219i spectre bidimensionale homo \u0219i heteronucleare (COSY, HMQC, HMBC), utiliz\u00e2nd programului Bruker TopSpin 3.2 pentru \u00eenregistrarea \u0219i prelucrarea spectrelor.<\/p>\n<p>Spectrometrul RMN este utilizat \u00een principal pentru determinarea structurii compu\u0219ilor organici mic \u0219i macro moleculari, a complec\u0219ilor, a compu\u0219ilor naturali izola\u021bi, urm\u0103rirea cineticii de reac\u021bie precum \u0219i determinarea compozi\u021biei \u00een amestecuri. Capul de prob\u0103 TXI de 1 mm este utilizat \u00eendeosebi pentru cantit\u0103\u021bi de compu\u0219i la nivel de micrograme, astfel fiind ideal pentru fluide biologice sau alimentare.<\/p>\n<p><img loading=\"lazy\" class=\"size-medium wp-image-1150 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-300x202.jpg\" alt=\"\" width=\"300\" height=\"202\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-300x202.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-1024x688.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-768x516.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-1536x1032.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-2048x1376.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-03-UV-VIS-01-CERNESIM-624x419.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Spectrofotometru UV-VIS, Specord 210 Plus, Analytik Jena, Germania<\/strong><\/p>\n<p>Spectrofotometrul Specord 210 Plus este capabil s\u0103 fac\u0103 analize spectrofotometrice de absorbant\u0103, transmitan\u021b\u0103, reflectant\u0103 \u0219i energie pentru probe lichide \u0219i solide, \u00een condi\u021bii de temperatur\u0103 controlat\u0103 folosind un sistem cu dublu fascicol real, cu rezolu\u021bie spectral\u0103 variabil\u0103.<\/p>\n<p>Monocromatorul instrumentului este cu re\u021bea de difrac\u021bie \u0219i optic\u0103 asferic\u0103 acoperit\u0103 cu cuar\u021b. \u00cen instrument sunt \u00eencorporate un filtru de oxid de holmiu \u0219i surs\u0103 de lumin\u0103 specifice domeniilor ultraviolet \u0219i vizibil (lamp\u0103 de halogen \u0219i deuteriu). Se poate opera \u00een domeniul 190-1100 nm cu l\u0103\u021bimi variabile ale benzilor spectrale (0,5\/1\/2\/4 nm). Acurate\u021bea lungimii de und\u0103 este de \u00b10,1 nm, iar stabilitatea m\u0103sur\u0103torilor de absorban\u021b\u0103 pe termen lung, dup\u0103 o or\u0103 de func\u021bionare, este de \u00b1 0,0005 fa\u021b\u0103 de valoarea citit\u0103 ini\u021bial.<\/p>\n<p>Spectrometrul Specord 210 Plus este dotat cu urm\u0103toarele accesorii:<\/p>\n<ul>\n<li>suport variabil pentru probe solide mici pentru determin\u0103ri transmitan\u021b\u0103;<\/li>\n<li>dispozitiv pentru sus\u021binerea probelor solide sub form\u0103 de filme sau pl\u0103ci;<\/li>\n<li>accesoriu pentru m\u0103sur\u0103tori de transmitan\u021b\u0103 \u0219i reflectan\u021b\u0103 difuz\u0103, prev\u0103zut cu sfer\u0103 integratoare, capabil s\u0103 lucreze \u00een domeniul de lungime de und\u0103 cuprins \u00eentre 200-1100 nm, cu suport pentru probe solide care s\u0103 permit\u0103 \u0219i analiza de pudre;<\/li>\n<li>sistem automat de aspirare probe pentru m\u0103sur\u0103tori de lichide f\u0103r\u0103 schimbarea cuvei cu prob\u0103, prev\u0103zut cu suport de cuve variabil, pentru cuve de 10\/20\/50 mm;<\/li>\n<li>suport de cuve termostatat, cu agitare (temperatura sistemului variaz\u0103 cel pu\u021bin \u00een intervalul 10 p\u00e2n\u0103 la 60 <sup>o<\/sup>C);<\/li>\n<li>sond\u0103 cu fibr\u0103 optic\u0103 cu suport adaptor pentru sond\u0103 \u0219i o pereche fibr\u0103 optic\u0103 tip UV pentru domeniul 240-1100 nm.<\/li>\n<\/ul>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1151 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-300x159.jpg\" alt=\"\" width=\"300\" height=\"159\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-300x159.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-1024x542.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-768x406.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-1536x813.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-2048x1084.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-04-LC-ICP-MS-01-CERNESIM-624x330.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Cromatograf de Lichide \u0219i Spectrometru de Mas\u0103 cu Plasm\u0103 Cuplat\u0103 Inductiv, 7700X ICP-MS cuplat cu Infinity LC 1260 Series, Agilent Technologies, SUA<\/strong><\/p>\n<p>Tehnica LC-ICP-MS este folosit\u0103 pentru detectarea ionilor atomici din diverse probe \u0219i reprezint\u0103 una dintre tehnicile cele mai puternice ale spectrometriei moleculare pentru identificarea substan\u021belor necunoscute \u0219i realizarea de studii structurale \u00een chimie, medicin\u0103 sau \u0219tiin\u021ba materialelor.<\/p>\n<p>Sistemul Infinity 1260 LC poate fi folosit at\u00e2t \u00een regim izocratic c\u00e2t \u0219i \u00een gradient cu p\u00e2n\u0103 la 4 solven\u021bi \u0219i permite o presiune maxim\u0103 de operare de 600 bari \u0219i un debit maxim al fazei mobile de 10 mL\/min. Sistemul de preluare automat\u0103 a probei este conceput \u00een a\u0219a fel \u00eenc\u00e2t s\u0103 mic\u0219oreze timpul de analiz\u0103, \u00een acela\u0219i timp m\u0103rind sensibilitatea, rezolu\u021bia \u0219i precizia. Compartimentul coloanei este termostatat, \u00een acest mod fiind posibil\u0103 \u00eenc\u0103lzirea sau r\u0103cirea coloanelor cu scopul de a ob\u021bine reproductibilitate a timpilor de reten\u021bie la un nivel ridicat.<\/p>\n<p>Instrumentul ICP-MS 7700X include un analizor pentru elemente \u00een urme, cu generator de RF cu frecven\u021b\u0103 rapid\u0103, cu dispozitiv de introducerea matricei, sistem de generare a reac\u021biei \u0219i un sistem cuadrupol hiperbolic de \u00eenalt\u0103 frecven\u021b\u0103.<\/p>\n<p>Instrumentul acoper\u0103 domeniul de mas\u0103 2-260 amu cu o vitez\u0103 de salt a maselor (de la Li la U) de 56,6 milioane amu\/s. Viteza de scanare (de la Li la U, colectarea datelor la 40 de mase) este &gt;3000 amu\/sec, rezolu\u021bia de mas\u0103 &lt;0,3 amu \u0219i sensibilitatea de abunden\u021b\u0103 de 5\u00d710<sup>-7<\/sup> pentru mase mici \u0219i de 10<sup>-7<\/sup> pentru mase mari. Limite de detec\u021bie &lt;0,1 ng\/L sunt atinse pentru <sup>115<\/sup>In \u0219i de 0,1 ng\/L pentru <sup>209<\/sup>Bi. Precizia raportului isotopic <sup>107<\/sup>Ag\/<sup>109<\/sup>Ag este mai bun\u0103 de 0,1.<\/p>\n<p>Analizorul de mas\u0103 folose\u0219te un analizor de tip quadrupol de mare frecven\u021b\u0103 (minim 3 MHz), cu distribu\u021bie hiperbolic\u0103, asigur\u00e2nd transmisie superioar\u0103 a ionilor, rezolu\u021bie \u0219i sensibilitate necesar\u0103 la utilizarea unor set\u0103ri standard.<\/p>\n<p>Detectorul este sub forma unui multiplicator electronic tip dinod\u0103 ce asigur\u0103 liniaritate pe un domeniu mare \u0219i poate lucra \u00een mod dual: puls la concentra\u021bii mici \u0219i \u00een mod analog pentru concentra\u021bii mari.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1152 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture3-300x143.png\" alt=\"\" width=\"300\" height=\"143\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture3-300x143.png 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture3-768x366.png 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture3-624x298.png 624w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture3.png 943w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Microscopie Electronic\u0103 de Baleaj, SEM Quanta 250, FEI Company, UK<\/strong><\/p>\n<p>SEM Quanta 250 este un instrument cu poten\u021bial ridicat de a fi utilizat \u00een \u0219tiin\u021ba materialelor, chimia mediului, pentru a investiga o larg\u0103 varietate de materiale \u0219i pentru a caracteriza structura \u0219i compozi\u021bia aerosolilor, nano-particulelor, poluan\u021bilor, datorit\u0103 domeniului foarte mare de presiuni de lucru \u00een camera probei, plec\u00e2nd de la 6\u00d710<sup>-4<\/sup> Pa \u0219i p\u00e2n\u0103 la 2600 Pa.<\/p>\n<p>Microscopul SEM Quanta 250 este solu\u021bia optim\u0103 pentru analize de imagine \u0219i de compozi\u021bie chimic\u0103 a probelor conductoare \u0219i neconductoare f\u0103r\u0103 preparare anterioar\u0103 a acestora precum \u0219i studierea in-situ a modificarii probelor \u00een procese de hidratare \u0219i deshidratare. Instrumentul se poate cupla cu alte tehnici de analiz\u0103 cum ar fi spectroscopia de raze X, difrac\u021bia electronilor retro-\u00eempr\u0103\u0219tia\u021bi \u0219i spectrometria de energie dispersiv\u0103. SEM Quanta 250 prezint\u0103 avantaje precum:<\/p>\n<ul>\n<li>se pot efectua m\u0103sur\u0103tori dinamice, <em>in situ<\/em>;<\/li>\n<li>se pot observa transform\u0103ri de faz\u0103, cristaliz\u0103ri, \u00een timpul ciclurilor de umiditate \u0219i temperatur\u0103;<\/li>\n<li>se pot analiza particule \u00een suspensii, procesul de coroziune a metalelor.<\/li>\n<\/ul>\n<p>Instrumentul folose\u0219te o surs\u0103 de wolfram, ce genereaz\u0103 un fascicul de electroni de energie \u00eenalt\u0103. \u00cen urma interac\u021biunii dintre prob\u0103 \u0219i fasciculul incident se genereaz\u0103 o serie de semnale bazate pe emisia electronilor secundari (SE), electronilor retro-\u00eempr\u0103\u0219tia\u021bi (BSE) \u0219i a razelor X caracteristice.<\/p>\n<p>Instrumentul opereaz\u0103 \u00een 3 moduri: High Vacuum (HV) sau vacuum \u00eenaintat \u2013 mod conven\u021bional (&lt;1.3\u00d710<sup>-2 <\/sup>Pa) pentru analiza probelor conductoare, Low Vacuum (LV) sau vacuum preliminar pentru analiza probelor solide, pulberilor \u0219i straturilor neconductoare, f\u0103r\u0103 preparare suplimentar\u0103 a probei (metalizare) (~10<sup>2<\/sup> Pa) \u0219i ESEM (~10<sup>4<\/sup> Pa) (Environmental Scanning Electron Microscopy &#8211; vacuum extins) \u00een care presiunea \u00een camera specimenului se poate seta prin software \u00een pa\u0219i \u0219i \u00een mod continuu \u00eentre 10 &#8211; 2600 Pa, pentru analiza probelor umede \u0219i care pot emana gaze (de exemplu probe de natura biologic\u0103, emulsii con\u021bin\u00e2nd nanoparticule, etc.).<\/p>\n<p style=\"text-align: justify\">SEM Quanta 250 este prev\u0103zut cu un detector EDX cu Siliciu Drift (SDD) de tip Apollo X care asigur\u0103 o rezolu\u021bie garantat\u0103 de 131 eV sau mai bun\u0103. Exist\u0103 posibilitatea de cuantificare elemente \u00eencep\u00e2nd (inclusiv) de la Beriliu, p\u00e2n\u0103 la Americiu.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1154 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-300x212.jpg\" alt=\"\" width=\"300\" height=\"212\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-300x212.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-1024x723.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-768x542.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-1536x1084.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-2048x1445.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-06-VERTEX70-01-CERNESIM-624x440.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Spectrofotometru infraro\u0219u cu Transformat\u0103 Fourier, FT-IR Vertex-70, Bruker Optik, Germania<\/strong><\/p>\n<p>FTIR Vertex-70 este un spectrofotometru cu transformat\u0103 Fourier care permite investigarea domeniului spectral 8500-350 cm<sup>-1<\/sup>. Este dotat cu o surs\u0103 Globar (SiC) pentru domeniul IR mijlociu \u0219i lamp\u0103 de halogen cu filament de Wolfram pentru domeniul IR apropiat \u0219i vizibil. Detectorul DLaTGS cu fereastr\u0103 de KBr faciliteaz\u0103 investigarea domeniului spectral 12000-250 cm<sup>-1<\/sup>. Interferometrul ROCKSOLID, cu aliniere permanent\u0103, este echipat cu un laser de HeNe, 633 nm, 1 mW.<\/p>\n<p>FTIR Vertex-70 este dotat cu accesorii care includ un modul ATR \u0219i un modul RAMAN II. Modulul ATR (reflexie total\u0103 atenuat\u0103), prev\u0103zut cu cristal de diamant, permite investigarea direct\u0103 a unor probe solide, lichide, paste, geluri, \u0219i materiale greu de rezolvat. Modulul RAMAN II permite investigarea urm\u0103toarelor domenii spectrale:<\/p>\n<ul>\n<li>3500-70 cm<sup>-1<\/sup> pentru laserul cu \u03bb = 1064 nm;<\/li>\n<li>4500-70 cm<sup>-1<\/sup> pentru laserul cu \u03bb = 976 nm;<\/li>\n<li>4100-70 cm<sup>-1<\/sup> pentru laserul cu \u03bb = 758 nm.<\/li>\n<\/ul>\n<p>Rezolu\u021bia atins\u0103 pe modulul RAMAN II este mai bun\u0103 de 0,8 cm<sup>-1<\/sup> iar acurate\u021bea num\u0103rului de und\u0103 este mai bun\u0103 de 0,01 cm<sup>-1<\/sup>.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1156 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-300x133.jpg\" alt=\"\" width=\"300\" height=\"133\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-300x133.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-1024x453.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-768x340.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-1536x680.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-2048x907.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-08-FLUORIM-01-CERNESIM-624x276.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Spectrofluorimetru, FLS-920s, Edinburgh Instruments, UK<\/strong><\/p>\n<p>Spectrofluorimetrul FLS-920s este un sistem modular, cu baleiaj spectral, destinat m\u0103sur\u0103torilor de fluorescen\u021b\u0103 \u00een regim sta\u021bionar (steady-state) respectiv pentru achizi\u021bia spectrelor de excitare \u0219i emisie \u00een domeniul UV-VIS.<\/p>\n<p>Este un instrument echipat cu surs\u0103 continu\u0103 de radia\u021bie, lampa de Xenon 450W (f\u0103r\u0103 producere de ozon). Sensibilitatea aparatului asigur\u0103 producerea unui semnal minim de 750000 impulsuri\/secund\u0103 \u0219i raportul semnal\/zgomot este mai bun de 6000:1 pentru spectrul RAMAN al apei (m\u0103surat la 350 nm excitare \u0219i 397 nm emisie, cu 1 secund\u0103 timp de integrare si 5 nm l\u0103rgime de band\u0103). Lampa de Xenon, continu\u0103, model Xe900, 450W, acoper\u0103 domeniul spectral 230 nm &#8211; 1000 nm.<\/p>\n<p>Monocromatorul de excitare TMS300-X este prev\u0103zut cu o re\u021bea de difrac\u021bie de 1800 linii\/mm, optimizat\u0103 la 250 nm, rezolu\u021bie de 0,05 nm, precizie a lungimii de und\u0103 de \u00b1 0,2 nm, repetabilitate a lungimii de und\u0103 de \u00b1 0,1 nm \u0219i vitez\u0103 de deplasare a re\u021belei de 200 nm\/s<strong>.<\/strong><\/p>\n<p>Monocromatorul de emisie TMS300-M, dezvoltat dup\u0103 un design Czerny Turner, asigur\u0103 o distan\u021b\u0103 focal\u0103 de 300 mm, selectarea fantei de intrare prin intermediul unei re\u021bele de difrac\u021bie cu 1800 linii\/mm, optimizat\u0103 la 500 nm. Rezolu\u021bia atins\u0103 este de 0,05 nm, precizia lungimii de und\u0103 este de \u00b1 0,2 nm, repetabilitatea lungimii de und\u0103 este de \u00b10,1 nm, viteza de deplasare a re\u021belei de 200 nm\/s \u0219i l\u0103rgimea benzii spectrale de 0,05-18 nm.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1157 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture4-300x169.png\" alt=\"\" width=\"300\" height=\"169\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture4-300x169.png 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture4-768x434.png 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture4-624x352.png 624w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/Picture4.png 949w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Cromatograf de lichide cuplat cu spectrometru de mas\u0103, LC-MS-ToF, Agilent Technologies, SUA<\/strong><\/p>\n<p>Sistemul LC-MS-ToF rezultat\u0103 din tandemul \u00eentre cromatografia de lichide (LC) \u0219i spectrometria de mas\u0103 cu timp de zbor (MS-TOF). Instrumentul LC-MS-TOF este dezvoltat \u00een baza unui concept modular \u00een care fiecare component\u0103 joac\u0103 un rol bine definit.<\/p>\n<p>Pompa sistemului HPLC asigur\u0103 o precizie a debitului mai bun\u0103 de 0,07% RSD pe baza timpului de reten\u021bie, o acurate\u021be a debitului de \u00b11% pentru un domeniu de debit cuprins \u00eentre 0,2 \u0219i 10 mL\/min. Pompa poate opera corespunz\u0103tor \u00een domeniul presiunilor de la 0 la 600 bari \u0219i domeniul de pH 1,0 &#8211; 12,5. Termostatul coloanei (model G1316A) asigur\u0103, \u00een intervalul temperatur\u0103 ambiant\u0103 p\u00e2n\u0103 la 80 <sup>o<\/sup>C, o stabilitate a temperaturii de minim \u00b1 0,15 grade.<\/p>\n<p>Injectorul manual permite injectarea unor volume de p\u00e2n\u0103 la 500 \u00b5L. Injectorul automat asigur\u0103 o precizie la injec\u021bie de 0,25% RSD pentru un domeniu de v\u00e2scozitate a probelor cuprins \u00eentre 0,2-5 cp. Volumul de injectare poate varia \u00een trepte de 0,1 \u00b5L \u00eentre 1 \u0219i 100 \u00b5L.<\/p>\n<p>Spectrometrul de Mas\u0103 cu Timp de Zbor acoper\u0103 domeniul m\/z \u00eentre 25-20000. Detectorul are sursa de ionizare de tip electrospray \u0219i asigur\u0103 o acurate\u021be a masei egal\u0103 sau mai bun\u0103 de 2 ppm. Baze de date pentru pesticide (1500 compu\u0219i) \u0219i compu\u0219i cu ac\u021biune toxicologic\u0103 (5000 compu\u0219i) permit investigarea unor sisteme complexe.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1159 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-300x215.jpg\" alt=\"\" width=\"300\" height=\"215\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-300x215.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-1024x735.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-768x551.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-1536x1103.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-2048x1470.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-11-HPLC-DAD-01-CERNESIM-624x448.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Cromatograf de Lichide cu detector dublu (Diode Array \u0219i Fluorescen\u021b\u0103), LC-DAD-FL, Agilent Technologies, SUA<\/strong><\/p>\n<p>UHPLC 1290 Infinity este un sistem modular incluz\u00e2nd pompe, autoinjector, termostate \u0219i detectoare tip DAD (diode array detector) \u0219i de fluorescen\u021b\u0103. Pompa binar\u0103 G4220 permite un domeniu de setare al debitului \u00eentre 0,001-5 mL\/min, cu increment de 0,001 mL\/min, iar domeniul de operare pentru presiune este de p\u00e2n\u0103 la 1200 bari. \u00cen compartimentul termostatat al coloanelor (model G1316C), conferind o stabilitate a temperaturii de +\/-0.05 <sup>o<\/sup>C, pot fi montate p\u00e2n\u0103 la 3 coloane de maxim 30 cm lungime.<\/p>\n<p>Autoinjectorul este prev\u0103zut cu un dispozitiv\u00a0 care acoper\u0103 domeniul de injectare 0,1-20 miocrolitri, cu precizie &lt;0.25 % RSD de la 5 la 20 \u00b5L \u0219i acurate\u021be de \u00b11%. Detectorul DAD (model G4212A) este prev\u0103zut cu o re\u021bea de 1024 diode de \u00eenalt\u0103 rezolu\u021bie \u0219i o lamp\u0103 de deuteriu (cu timp mare de via\u021b\u0103).<\/p>\n<p>Acurate\u021bea lungimii de und\u0103 este de \u00b11 nm, cu autocalibrare dup\u0103 liniile deuteriului \u0219i verificare cu filtru de oxid de holmiu \u00eencorporat. Viteza de achizi\u021bie a datelor spectrale selectabil\u0103 p\u00e2n\u0103 la 160 Hz.<\/p>\n<p>Detectorul de fluorescen\u021b\u0103 3D (model G1321A), de tip multisemnal, asigur\u0103 atingerea unei limite de detec\u021bie de 10 fg antracen. Repetabilitatea lungimii de und\u0103 pe acest detector este de \u00b10,2 nm, excitarea se poate realiza la orice valoare a lungimii de und\u0103 \u00een intervalul 200-700 nm \u0219i emisia \u00een intervalul 280-900 nm.<\/p>\n<p>Instrumentul UHPLC 1290 Infinity permite investigarea probelor din categoriile produselor farmaceutice, alimentelor, \u0219tiin\u021bei vie\u021bii, mediului, criminalisticii etc.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1160 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-300x94.jpg\" alt=\"\" width=\"300\" height=\"94\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-300x94.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-1024x320.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-768x240.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-1536x479.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-2048x639.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-12-SUNSET-01-CERNESIM-624x195.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/strong><\/p>\n<p><strong>Analizor de Carbon Organic\/Elemental (OC\/EC), SUNSET Laboratory Inc., USA<\/strong><\/p>\n<p>Instrumentul SUNSET Laboratory OC\/EC permite analiza \u0219i discriminarea pe cale termo-optic\u0103 a carbonului organic sau a carbonului optic transparent (OC) \u0219i a carbonului elemental sau a carbonului cu absorbtivitate optic\u0103 (EC), ca forme existente \u00een materia particulat\u0103.<\/p>\n<p>\u00cenc\u0103lzirea la 870 \u00baC a unui cuptor de cuar\u021b, purjat continuu cu heliu (mediu non-oxidativ), permite desorb\u021bia termic\u0103 a compu\u0219ilor organici \u0219i, \u00eentr-o mai mic\u0103 m\u0103sur\u0103, a produ\u0219ilor de piroliz\u0103 \u00eentr-un cuptor de oxidare din dioxid de mangan care asigur\u0103 conversia cantitativ\u0103 a compu\u0219ilor anterior men\u021biona\u021bi la CO<sub>2<\/sub>. \u00cen curent de H<sub>2<\/sub> \u0219i \u00een prezen\u021ba unui catalizator \u00eenc\u0103lzit din nichel este asigurat\u0103 conversia cantitativ\u0103 a CO<sub>2<\/sub> la CH<sub>4<\/sub> m\u0103surat prin intermediul unui detector cu ionizare \u00een flac\u0103r\u0103 (FID).<\/p>\n<p>R\u0103cirea cuptorului la 600 \u00baC \u0219i purjarea unui amestec oxidant de gaze (heliu\/oxigen) faciliteaz\u0103 determinarea carbonului elemental prin oxidare de pe filtru \u0219i \u00een interiorul cuptorului de oxidare. Artefactele rezultate ca urmare a producerii proceselor de piroliz\u0103 sunt corectate \u00een baza caracteristicii carbonului elemental de a absorbi puternic lumina. O radia\u021bie laser ro\u0219ie (laser de He-Ne) str\u0103bate camera probei \u0219i transmitan\u021ba laserului este monitorizat\u0103 odat\u0103 cu parcurgerea rampei corespunz\u0103toare de temperatur\u0103. Arderea carbonului organic conduce la sc\u0103derea transmitan\u021bei laserului. Pentru carbonul elemental este necesar\u0103 corec\u021bie func\u021bia de contribu\u021biile aduse prin procesul de piroliz\u0103.<\/p>\n<p style=\"text-align: justify\"><img loading=\"lazy\" class=\"size-medium wp-image-1161 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-300x91.jpg\" alt=\"\" width=\"300\" height=\"91\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-300x91.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-1024x311.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-768x233.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-1536x467.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-2048x623.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-13-CONTRAA-01-CERNESIM-624x190.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><strong>Spectrofotometru de Absorb\u021bie Atomic\u0103 de \u00cenalt\u0103 Rezolu\u021bie, cu Surs\u0103 Continu\u0103 (HR-CS-AAS) cu flac\u0103r\u0103, cuptor de grafit, sistem de hidruri \u0219i sistem de solide, ContrAA 700 Analytik Jena, Germania<\/strong><\/p>\n<p>Spectrometrul de Absorb\u021bie Atomic\u0103 de \u00cenalt\u0103 Rezolu\u021bie, cu Surs\u0103 Continu\u0103 (HR-CS-AAS) este un instrument capabil de determin\u0103ri mono- \u0219i multi-element secven\u021biale prin procedeul de absorb\u021bie atomic\u0103 din probe lichide \u0219i solide. ContrAA 700 este un aparat compact, complet automatizat, care cuprinde un sistem de analiz\u0103 a probelor folosind ca surs\u0103 de atomizare flac\u0103ra de acetilen\u0103-aer\/N<sub>2<\/sub>O \u0219i cuptorul de grafit. Instrumentul este dotat \u0219i cu un sistem de generare de hidruri \u0219i un sistem de analiz\u0103 direct\u0103 a probelor solide, acestea \u00eenlocuind configura\u021bia standard, func\u021bie de aplica\u021bie.<\/p>\n<p>Domeniul spectral acoperit de Lampa cu Arc Scurt de Xe este cuprins \u00eentre 185 \u0219i 900 nm, cu posibilitatea ob\u021binerii unor benzi spectrale de cel mult 0,2 nm pentru radia\u021bia de 200 nm. Cuptorul de grafit poate ajunge la o temperatur\u0103, \u00een interior, de maxim 3000 <sup>o<\/sup>C. Procesele de ardere din cuptor sunt monitorizate prin intermediul unui sistem video.<\/p>\n<p>Spectrometrul este echipat cu sisteme automate de introducere a probelor, care permit dilu\u021bia automat\u0103, cu posibilitate de preparare automat\u0103 a etaloanelor, realizarea automat\u0103 de adi\u021bii standard \u0219i programarea automat\u0103 a ciclurilor de cl\u0103tire \u0219i sp\u0103lare, din soft. Sistemul de hidruri, cu mod de lucru continuu, permite determinarea de Hg, As, Se, Sb, Te, Bi \u0219i Sn.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1162 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-300x63.jpg\" alt=\"\" width=\"300\" height=\"63\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-300x63.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-1024x216.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-768x162.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-1536x324.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-2048x433.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-14-TOC-TN-01-CERNESIM-624x132.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Analizor Multi N\/C 3100, Analytic Jena, Germany<\/strong><\/p>\n<p>Analizorul Multi N\/C 3100 este un instrument capabil s\u0103 determine con\u021binutul de carbon total, carbon organic total, carbon anorganic total, carbonul organic volatil \u0219i nevolatil \u0219i azot total din probe lichide \u0219i solide (soluri). Instrumentul, de tip modular, este prev\u0103zut cu dou\u0103 detectoare, unul de tip infraro\u0219u nedipersiv pentru carbon, realizat din materiale necorozive \u0219i f\u0103r\u0103 p\u0103r\u021bi \u00een mi\u0219care \u0219i unul de tip chemiluminescen\u021b\u0103 (CLD) pentru determin\u0103ri de azot total.<\/p>\n<p>Detectorul pentru carbon, echipat cu o surs\u0103 de radia\u021bie IR pulsant\u0103, de \u00eenalt\u0103 putere, cu optic\u0103 \u00eencapsulat\u0103 \u0219i microdetector de \u00eenalt\u0103 sensibilitate, permite detec\u021bia precis\u0103 a CO<sub>2<\/sub> cu focalizarea radia\u021biei. \u00cen cazul probelor lichide temperatura de combustie este de 950 <sup>o<\/sup>C \u00een timp ce la probele solide este de 1300 <sup>o<\/sup>C f\u0103r\u0103 aditivi. Analizorul permite analiza \u00eentr-un domeniu de concentra\u021bie de maxim 30000 mg C\/L, f\u0103r\u0103 dilu\u021bie, pentru probe lichide, \u00een timp ce \u00een probele solide instrumentul func\u021bioneaz\u0103 optim \u00eentr-un domeniu de p\u00e2n\u0103 la 500 mg C. Limita de detec\u021bie a analizorului la investigarea probelor lichide este de 50 \u00b5g C\/L.<\/p>\n<p>Analizorul este prev\u0103zut cu un sistem care permite introducerea probelor lichide \u00een flux \u0219i care asigur\u0103 \u0219i o sp\u0103lare automat\u0103 \u00een vederea prevenirii contamin\u0103rii de la o prob\u0103 la alta. Instrumentul este prev\u0103zut cu un autosampler de tip xyz cu 60 pozi\u021bii, care permite omogenizarea, acidifierea \u0219i purjarea individual\u0103 a probelor.<\/p>\n<p style=\"text-align: justify\"><strong><img loading=\"lazy\" class=\"size-medium wp-image-1163 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-300x131.jpg\" alt=\"\" width=\"300\" height=\"131\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-300x131.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-1024x447.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-768x335.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-1536x671.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-2048x894.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L1-15-VCD-FTIR-01-CERNESIM-624x272.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Spectrometru VCD-FTIR, CHIRAL<em>IR<\/em>2X<em><sup>TM<\/sup><\/em><\/strong><strong>, BioTools, UK-USA<\/strong><\/p>\n<p>CHIRAL<em>IR<\/em>2X este un instrument de concep\u021bie nou\u0103 care func\u021bioneaz\u0103 pe baza spectroscopiei de dicroism circular vibra\u021bional (VCD) \u00een domeniul IR Apropiat (NIR) sau Mijlociu (MIR). Spectrometrul de \u00eenalt\u0103 performan\u021b\u0103 cu transformat\u0103 Fourier pe domeniul infraro\u0219u mediu \u0219i dicrosim circular vibra\u021bional (MIR FTIR-VCD) permite realizarea unor analize conforma\u021bionale pentru diverse probe chirale, naturale (proteine, acizi nucleici) \u0219i sintetice (produse farmaceutice).<\/p>\n<p>Sistemul este prev\u0103zut cu o unitate <em>Sync<\/em>RoCell \u2013 o platform\u0103 rotativ\u0103 cu cuv\u0103 (dinamic\u0103) pentru eliminarea artefactelor, care poate fi utilizat\u0103 pentru m\u0103sur\u0103tori FT-IR \u0219i VCD at\u00e2t ale probelor lichide c\u00e2t \u0219i ale probelor solide. Datele spectrale ob\u021binute pot fi comparate cu rezultatele calculelor <em>ab<\/em><em> initio<\/em> \u00een vederea determin\u0103rii configura\u021biilor absolute pentru moleculele nou sintetizate. Este posibil\u0103 determinarea purit\u0103\u021bii enantiomerice \u00een cazul moleculelor a c\u0103ror configura\u021bie absolut\u0103 este deja cunoscut\u0103.<\/p>\n<p>Detectorul MCT (mercur-cadmiu-telur), r\u0103cit cu azot lichid, permite atingerea unor rezolu\u021bii de 4 cm<sup>-1<\/sup> pentru moleculele mici \u0219i de 8 cm<sup>-1<\/sup> pentru pentru proteinele simple. CHIRALIR2X permite achizi\u021bia simultan\u0103 a interferogramelor \u00een IR \u0219i VCD. Prezen\u021ba unei surse duble \u00een sistemul CHIRALIR2X permite \u00eembun\u0103t\u0103\u021birea raportului semnalul-zgomot de ~3,6 ori fa\u021b\u0103 de orice alt sistem.<\/p>\n<p>Instrumentul permite operarea \u00een domeniul spectral 6500-800 cm<sup>-1<\/sup>, f\u0103r\u0103 a schimba filtre, dar poate fi configurat pentru a m\u0103sura \u00een regim de band\u0103 \u00eengust\u0103 \u0219i domeniul spectral 2000-850 cm<sup>-1<\/sup>.<\/p>\n<p>Investigarea probelor organice nepolare se realizeaz\u0103 \u00een CCl<sub>4<\/sub>, a probelor organice polare \u00een DMSO-d<sub>6<\/sub> \u0219i a probelor biologice \u00een solu\u021bii tampon sau al\u021bi solven\u021bi adecva\u021bi. Se recomand\u0103 ca spectrele IR s\u0103 fie \u00eenregistrate \u00een domeniul 0,2 &#8211; 0,8 u.a. pentru intensit\u0103\u021bile semnalelor de interes, \u00een timp ce spectrele VCD trebuie s\u0103 prezinte absorban\u021be de 1,0 pentru fiecare semnal de interes pentru a evita contribu\u021bia adus\u0103 de zgomotul de fond.<\/p>\n<p><strong><img loading=\"lazy\" class=\"size-medium wp-image-1208 alignright\" src=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-300x199.jpg\" alt=\"\" width=\"300\" height=\"199\" srcset=\"https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-300x199.jpg 300w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-1024x680.jpg 1024w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-768x510.jpg 768w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-1536x1020.jpg 1536w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-2048x1361.jpg 2048w, https:\/\/cernesim.uaic.ro\/tmp\/files\/2020\/12\/L3-04-IC-THERMO-02-CERNESIM-624x415.jpg 624w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>Cromatograf ionic, ICS 5000 Thermo Dionex, USA<\/strong><\/p>\n<p>Cromatograful ionic ICS 5000 Dionex este un instrument potrivit pentru analiza speciilor ionice solubile \u00een ap\u0103 tip cationi (Na<sup>+<\/sup>, NH<sub>4<\/sub><sup>+<\/sup>, K<sup>+<\/sup>, Ca<sup>2+<\/sup>, Mg<sup>2+<\/sup>) \u0219i anioni (F<sup>&#8211;<\/sup>, Cl<sup>&#8211;<\/sup>, Br<sup>&#8211;<\/sup>, NO<sub>3<\/sub><sup>&#8211;<\/sup>, NO<sub>2<\/sub><sup>&#8211;<\/sup>, SO<sub>4<\/sub><sup>2-<\/sup>, PO<sub>4<\/sub><sup>3-<\/sup>). \u00cen cromatografia ionic\u0103 anali\u021bii sunt, fie ioni rezulta\u021bi din disocierea electroli\u021bilor \u00een solu\u021bie, fie ioni rezulta\u021bi din derivatizarea compu\u0219ilor non-ionici (complexarea \u00een vederea determin\u0103rii unui ligand organic) sau din electroli\u021bi slabi.<\/p>\n<p>Detectorul de conductivitate reprezint\u0103 metoda de detec\u021bie modern\u0103 \u00een analizele care au la baz\u0103 separarea \u0219i identificarea componen\u021bilor unui analit. De altfel, detectorii conductometrici sunt recunoscu\u021bi ca fiind sisteme caracterizate de sensibilitate ridicat\u0103, stabilitate, flexibilitate, acurate\u021be \u0219i reproductibilitate, \u0219i de capacitate mare de a furniza date de \u00eencredere. \u00cen detectorii conductometrici, \u00een general, celula detectorului este localizat\u0103 \u00eentr-o incint\u0103 special\u0103 de reglare a temperaturii, care are rolul de a izola celula detectorului de fluctua\u021biile externe de temperatur\u0103. Un schimb\u0103tor de c\u0103ldur\u0103 unic, \u00eenc\u0103lze\u0219te faza mobil\u0103 \u0219i proba \u00eenainte ca acestea s\u0103 ajung\u0103 \u00een celula detectorului. Aceste dou\u0103 tr\u0103s\u0103turi furnizeaz\u0103 stabilitatea liniei de baz\u0103 (se elimin\u0103 influen\u021ba curentului indus de temperatur\u0103 care este \u00eent\u00e2lnit\u0103 la alte tipuri de detectoare).<\/p>\n<p>Faza mobil\u0103 poate fi constituit\u0103 din ap\u0103, electroli\u021bi puternici, dar \u0219i solu\u021bii de solven\u021bi organici polari \u00een ap\u0103. Instrumentul este prev\u0103zut cu supresori electrochimici (sau autosupresori) care au rolul de a sc\u0103dea conductivit\u0103\u021bile specifice fazelor mobile utilizate \u0219i de a le \u00eembun\u0103t\u0103\u021bi (cre\u0219te) pe cele specifice anali\u021bilor de interes.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Difractometru de raze X pentru monocristale cu surs\u0103 dual\u0103, SuperNova, Agilent Technologies, UK Difractometrul este prev\u0103zut cu o surs\u0103 dual\u0103 (Nova\u2122 &#8211; Cu \u0219i Mova\u2122 &#8211; Mo), ideal\u0103 pentru analiza cristalelor care con\u021bin at\u00e2t atomi cu o densitate electronic\u0103 redus\u0103 c\u00e2t \u0219i atomi cu o densitate electronic\u0103 ridicat\u0103. Instrumentul are capacitatea de colectare a datelor, [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":0,"parent":45,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/pages\/50"}],"collection":[{"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/comments?post=50"}],"version-history":[{"count":9,"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/pages\/50\/revisions"}],"predecessor-version":[{"id":1397,"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/pages\/50\/revisions\/1397"}],"up":[{"embeddable":true,"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/pages\/45"}],"wp:attachment":[{"href":"https:\/\/cernesim.uaic.ro\/index.php\/wp-json\/wp\/v2\/media?parent=50"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}